Click Image for Gallery
The LISENS grid light curtains are non-contact sensors that are used for protecting crushing, shearing and impact hazards on many types of automatic industrial doors. (PLEASE NOTE: LISENS grid is not currently suitable for use on outdoor automatic gate systems).
Maintain the aesthetic of your door system and allow high operating speeds, thanks to its low profile design and concealed installation the LISENS grid operates discreetly and intelligently.
Features
- Protective height of 750mm and overall height of 850mm (BH)
- Shipping friendly: short packaging length of 1m
- Universally connectable: FSS, PNP, NPN (optional)
- Integrated evaluation electronics
- Integrated electronic alignment aid
- For closing speeds up to max. 2 m/s
- For flexible use: activatable blanking function
- Robust extruded aluminium housing
- Connecting cables with color-coded M8 snap connectors - easy to install, reverse polarity protected, flexible and economical
- The innovative optical sensor solution from ASO
- Made in Germany - developed and produced in the highest quality
Kit Contents
- P.01 - Light curtain Tx (transmitter unit)
- P.02 - Light curtain Rx (receiver unit)
- P.03 - Assembly clips
- P.04 - Screws for assembly clips
- P.05 - LISENS connecting cable
- P.06 - Controller connecting cable
Article Number
2301-0520
Manuals and Datasheets
ASO LISENS grid Safety Light Curtain Manual
ASO LISENS grid Safety Light Curtain Datasheet
Diagrams
Click diagrams to enlarge
Details | |
Casing | Aluminium |
Max. closing speed gate (vertical) | 2m/s |
Dimensions | |
Height | Protective Height - 850mm (BH) Height - 750mm |
Max. protective field width (switchable) | 10 m/5 m |
Weight (kg) | 1 |
Electrical Data | |
Current Consumption (A) | 60 mA |
Operating Voltage | 10-30 V DC |
Lighting Specifications | |
Ambient light safety | >100 k Lux |
Number of beams | 18 |
Performance Data | |
Operating Temperature | -10°C - + 50°C |
Safety Relay Data | |
Safety Category | Kat 2 Pl "c" |
According to the following standards | EN 12978 EN ISO 13849 Kat 2 PL "c" IEC 61496-2 EN 12453 Kap. 7 EN 12453 Kap. 5.5.1-C+D oder E Device |
Technical | |
Output signals | FSS PNP NPN (optional) |
Protection Level (IP) | 67 |